HIGH VOLTAGE OIL-IMMERSED TRANSFORMER

TECHNICAL DATASHEET

  1. General Information
    • Product: High Voltage Oil-Immersed Power Transformer
    • Type: Power Transformer for Transmission and Distribution
    • Cooling Method:
  • ONAN(Oil Natural, Air Natural)
  • ONAF(Oil Natural, Air Forced)
    • Installation: Indoor / Outdoor (IP-rated enclosures available)
    • Standards Compliance:
  • IEC 60076
  • IEEE C57
  • EN 50588
  1. Rated Specifications
ParameterDescription
Rated Power500 kVA – 100 MVA (customizable up to 500 MVA)
Rated Frequency50 Hz / 60 Hz
Number of PhasesThree-phase
Vector GroupDyn11 (other configurations available)
Cooling TypeONAN / ONAF (based on transformer size)
Insulation ClassClass A (55°C), Class B (80°C), Class F (100°C)
Duty TypeContinuous Operation
  1. Rated Voltages
SideVoltage
High Voltage (HV)33 / 66 / 110 / 132 / 150 / 220 / 330 kV
Low Voltage (LV)0.4 / 0.415 / 0.69 / 0.72 / 0.84 kV
Highest Voltage for EquipmentUp to 400 kV
  1. Tap Changer Configuration
    • Type: Off-Circuit Tap Changer (OC) / On-Load Tap Changer (OLTC)
    • Tap Range: ±2 × 2.5% (or ±5%)
    • Tap Locations: High-voltage side (other tap configurations available)
    • On-Load Tap Changer: Optional, for continuous voltage regulation under varying load conditions
  1. Insulation & Dielectric Strength
  • Winding Insulation: Paper-oil insulation system (vacuum-impregnated)
  • Insulation Class: F or H (depending on the transformer rating)
  • Creepage Distance: According to IEC 60076 standards
  • Lightning Impulse Withstand (BIL): Compliant with IEC 60076 standard for high voltage transformers
  1. Temperature Rise
ItemLimit
Winding Temperature Rise≤ 65°C (Class A) / ≤ 80°C (Class B) / ≤ 100°C (Class F)
Top Oil Temperature Rise≤ 50°C
Ambient TemperatureMax. 40°C, Min. −25°C
Relative Humidity≤ 95%
  1. Losses & Efficiency
  • No-Load Loss (Core Loss): As per IEC 60076 standards
  • Load Loss (Copper Loss): As per IEC 60076 standards
  • Efficiency: High-efficiency, low-loss design for energy conservation
  • Sound Level: ≤ 55 dB (depending on the transformer rating and configuration)
  • Operational Efficiency: Exceeds standard performance parameters for energy-efficient operation
  1. Core & Winding Construction
  • Core:
  • Cold-rolled grain-oriented silicon steel
  • Step-lap construction for minimal core losses
    • Windings:
  • Copper or Aluminum (as per customer specification)
  • Concentric windings with optimized short-circuit resistance
    • Insulation:
  • Paper-oil insulation (vacuum-impregnated process) for superior dielectric strength and long-term reliability
    • Tank:
  • Welded steel tank with corrosion-resistant coating for long operational life in harsh environments
    • Finish:
  • Outdoor applications are coated with anti-corrosion paint, available in custom RAL colors
  1. Standard Accessories
    • Conservator Tank: For expansion and contraction of transformer oil
    • Oil Level Indicator: Visual and electrical indicators for monitoring oil levels
    • Temperature Indicator: Thermometer or PT100 (for continuous monitoring)
    • Pressure Relief Device: For safe pressure release during abnormal conditions
    • Earthing Terminals: For safe grounding of the transformer
    • Rating Plate: Stainless steel plate with all key technical details
  1. Tests & Quality Assurance

Routine Tests (as per IEC 60076):

  • Measurement of winding resistance
  • Verification of transformer ratio and vector group
  • No-load loss and current measurement
  • Load loss and impedance measurement
  • Insulation resistance and dielectric tests

Type/Special Tests (upon request):

  • Lightning impulse withstand test
  • Temperature rise test under full load conditions
  • Noise level test according to IEC 60076-10
  • Short-circuit withstand test
  1. Operating Conditions
  • Installation Altitude: ≤ 1000 m (above sea level; higher altitudes available on request)
  • Ambient Temperature Range:
  • +40°C
  • −25°C (customizable for extreme climates)
    • Relative Humidity: ≤ 95%
    • Pollution Degree: PD2 (IEC 60076-11 standard)
    • Installation Location: Indoor / Outdoor with IP protection (IP44 or higher)
  1. Applications
  • High Voltage Transmission Systems
  • Substation Installations(Power Plants, Grid Substations)
  • Renewable Energy Plants(Solar, Wind Power)
  • Industrial Plants(Steel Mills, Petrochemical Facilities)
  • Critical Infrastructure(Data Centers, Hospitals, Airports)
  • Oil & Gas Platforms(Offshore and Onshore installations)
  1. Compliance & Certification

This High Voltage Oil-Immersed Transformer is designed, manufactured, and tested in accordance with international standards IEC 60076, IEEE C57, and EN 50588. It is ideal for reliable and efficient operation in power transmission, industrial applications, and renewable energy projects.

Notes for Special Requirements:

  • For Export: Ensure clear identification of Rated Voltagevs Highest Voltage for Equipment
  • For Outdoor Installations: Confirm IP-rated enclosuresto protect against environmental factors
  • On-Load Tap Changer (OLTC): Ideal for dynamic voltage regulation under fluctuating load conditions

Special Features: Custom configurations available for higher temperature classes, specific loss parameters, or enhanced monitoring systems