Oil-immersed transformer
Level 1 Energy Efficiency Oil-immersed Transformer

Details
MEDIUM VOLTAGE OIL-IMMERSED TRANSFORMER
TECHNICAL DATASHEET
- General Information
- Product: Medium Voltage Oil-Immersed Power Transformer
- Type: Distribution Transformer
- Cooling Method: ONAN (Oil Natural Air Natural)
- Installation: Outdoor / Indoor
- Applicable Standards: IEC 60076
- Ratings
| Item | Description |
| Rated Power | 50 kVA – 2500 kVA (up to 5000 kVA on request) |
| Rated Frequency | 50 Hz / 60 Hz |
| Number of Phases | Three-phase |
| Vector Group | Dyn11 (others available upon request) |
| Cooling Type | ONAN |
| Duty Type | Continuous |
- Rated Voltages
| Side | Voltage |
| High Voltage (HV) | 6 / 10 / 11 / 13.8 / 20 / 22 / 33 kV |
| Low Voltage (LV) | 0.4 / 0.415 / 0.48 / 0.69 kV |
| Highest Voltage for Equipment | Up to 36 kV |
- Tap Changer
- Type: Off-circuit tap changer
- Tapping Range: ±2 × 2.5% (or ±5%)
- Location: HV side
- On-load Tap Changer (OLTC): Optional
- Insulation Levels
| Highest Voltage | Power Frequency Withstand | Lightning Impulse Withstand (BIL) |
| 12 kV | 28 kV | 75 kV |
| 24 kV | 50 kV | 125 kV |
| 36 kV | 70 kV | 170 kV |
- Temperature Rise
| Item | Limit |
| Winding Temperature Rise | ≤ 65 K |
| Top Oil Temperature Rise | ≤ 60 K |
| Ambient Temperature | Max. 40°C |
- Losses and Efficiency
- No-load Loss: According to IEC 60076
- Load Loss: According to IEC 60076
- Efficiency: High efficiency, low loss design
- Sound Level: In compliance with IEC limits
- Insulating Oil
- Type: Mineral Insulating Oil
- Standard: IEC 60296
- Optional: Natural Ester Oil (FR3)
- Construction Details
- Core:
Cold-rolled grain-oriented silicon steel, step-lap construction - Windings:
Copper (Aluminum optional upon request) - Tank:
Welded steel tank, corrosion-resistant coating - Finish:
Outdoor anti-corrosion paint, RAL color optional
- Accessories (Standard)
- Conservator
- Oil level indicator
- Temperature indicator
- Pressure relief device
- Earthing terminals
- Rating plate (stainless steel)
- Tests
Routine Tests (IEC 60076):
- Measurement of winding resistance
- Ratio and vector group verification
- No-load loss and current
- Load loss and impedance
- Insulation tests
Type / Special Tests (Optional):
- Lightning impulse test
- Temperature rise test
- Sound level test
- Service Conditions
- Installation altitude: ≤ 1000 m above sea level
- Ambient temperature:
- Maximum: +40°C
- Minimum: −25°C (lower on request)
- Relative humidity: ≤ 95%
- Applications
- Utility distribution networks
- Industrial plants
- Commercial facilities
- Renewable energy systems
- Compact and pad-mounted substations
- Compliance Statement
The medium voltage oil-immersed transformer is designed, manufactured and tested in accordance with IEC 60076 standards and applicable international requirements.
-
- Products and Solutions
- Oil-immersed transformer
- Level 1 Energy Efficiency Oil-immersed Transformer