wordpress

Professional Transformer Manufacturer & Supplier
Fixed capacity reactor Fixed capacity reactor
Reactor

Fixed capacity reactor

Fixed capacity reactor
Details
  1. General Description

A High Voltage Reactor (also known as Inductor) is a type of electrical device used to limit short-circuit currents, compensate reactive power, and filter harmonic currents in high voltage transmission systems. These reactors are typically used in applications where high efficiency and reliability are required to support voltage regulation and reduce the impact of faults on power systems.

The most common types of high voltage reactors are:

  • Shunt Reactors: Connected in parallel to absorb reactive power and stabilize voltage.
  • Series Reactors: Connected in series to limit short-circuit currents or reduce fault levels.
  • Neutral Reactors: Connected to the neutral of the system to limit ground fault currents.
  1. Electrical Characteristics
ParameterSpecification
Rated Power1 MVA – 100 MVA (customizable)
Rated Voltage33 kV / 66 kV / 110 kV / 132 kV / 220 kV
Rated Current50 A – 5000 A (depending on voltage and design)
Inductance1 mH – 1000 mH (customizable)
Frequency50 Hz / 60 Hz
Connection TypeDelta / Wye (star)
Short-Time Withstand Current1.2–2 × rated current for 1 second
Overload Capability1.5 × rated current for 2–5 minutes (customizable)
  1. Types & Applications
TypeApplication
Shunt ReactorAbsorbs reactive power and stabilizes voltage in transmission systems
Series ReactorLimits short-circuit currents and reduces fault levels in high voltage networks
Neutral ReactorLimits ground fault currents in grounded systems
Harmonic Filter ReactorReduces harmonic distortion in industrial plants or renewable energy systems
  1. Mechanical & Construction Features
  • Core Material:
  • Dry-Type: Grain-oriented silicon steel
  • Oil-Immersed: Laminated magnetic steel for high efficiency
    • Windings: Copper or Aluminum, designed to withstand high short-circuit forces
    • Insulation System:
  • Dry-Type: Vacuum Impregnated Epoxy Resin (VPI)
  • Oil-Immersed: Paper-oil system (VPI optional for enhanced insulation)
    • Enclosure / Tank:
  • Oil-Immersed: Welded steel tank with anti-corrosion coating
  • Dry-Type: Ventilated enclosure, IP20–IP54 (customizable)
    • Finish: Powder coating, RAL color customizable
    • Mounting: Floor-mounted, Pad-mounted, or Flange-mounted as required
  1. Cooling & Temperature Characteristics
  • Cooling Methods:
  • Dry-Type: Air Natural (AN) / Air Forced (AF)
  • Oil-Immersed: ONAN / ONAF (Oil Natural, Air Natural / Oil Natural, Air Forced)
    • Winding Temperature Rise:
  • Dry-Type: ≤ 100°C (Class F) / ≤ 120°C (Class H)
    • Ambient Temperature: −25°C to +40°C (customizable for extreme climates)
    • Relative Humidity: ≤ 95%
  1. Losses & Efficiency
  • Core Loss (No-Load Loss): According to IEC 60076-6 standards
  • Copper Loss (Load Loss): Measured at rated current and temperature
  • Efficiency: High-efficiency design for reducing energy consumption
  • Sound Level: ≤ 55 dB (depending on size and configuration)
  1. Standard Accessories
  • Temperature Monitoring: PT100 temperature sensor or thermometer for continuous monitoring
  • Pressure Relief Device: For oil-immersed reactors to prevent overpressure conditions
  • Earthing Terminals: For safe and reliable grounding
  • Bushing / Terminal Connectors: For high and low voltage connections
  • Rating Plate: Stainless steel plate displaying key technical parameters
  1. Tests & Quality Assurance

Routine Tests (IEC 60076-6 / IEEE C57.16):

  • Winding resistance measurement
  • Inductance verification
  • Short-circuit withstand test
  • No-load loss and load loss measurement
  • Insulation resistance and dielectric tests

Type / Special Tests (Optional):

  • Partial discharge test (for dry-type reactors)
  • Temperature rise test under full load conditions
  • Lightning impulse withstand test
  • Noise level measurement
  1. Operating Conditions
  • Installation Altitude: ≤ 1000 m above sea level (higher altitudes available upon request)
  • Ambient Temperature:
  • +40°C
  • −25°C (customizable for extreme environments)
    • Relative Humidity: ≤ 95%
    • Pollution Degree: PD2 (IEC 60076-11)
    • Installation Location: Indoor / Outdoor (IP-rated enclosure as required)
  1. Applications
  • High Voltage Transmission Networks
  • Substations and Power Plants
  • Renewable Energy (Wind, Solar)
  • Industrial Plants (Motor Starting, Reactive Power Compensation)
  • Ground Fault Protection
  • Harmonic Filteringin industrial applications
  1. Compliance & Certification

The High Voltage Reactor is designed, manufactured, and tested in compliance with IEC 60076-6, IEEE C57.16, ANSI C57, and UL standards (where applicable). Suitable for reliable operation in high voltage transmission and distribution networks, industrial plants, and renewable energy systems.

  1. Customization Options
  • Custom voltages, inductance values, and current ratings
  • Special insulation classes for high-temperature or humid environments
  • Explosion-proof, fire-resistant, or low-noise designs available
  • Optional on-load tap changers or monitoring sensors

Conclusion

The High Voltage Reactor is an essential component for controlling voltage and current stability in power systems. With a wide range of applications from reactive power compensation to fault current limitation, these reactors are vital for maintaining efficient and safe operation of modern power grids and industrial systems. The flexibility in customization allows them to meet various specific needs of clients in different sectors, including renewable energy, industrial plants, and utilities.

DATA DOWNLOAD
  • I have read and agree to the Privacy Policy.
E-mail WhatsApp