wordpress

Professional Transformer Manufacturer & Supplier
216.7 MVA 525 kV transformer in Portland, USA 216.7 MVA 525 kV transformer in Portland, USA
Ultra-high voltage transformer

216.7 MVA 525 kV transformer in Portland, USA

216.7 MVA 525 kV transformer in Portland, USA
Details

ULTRA HIGH VOLTAGE (UHV) POWER TRANSFORMER

TECHNICAL DATASHEET

  1. General Information
    • Product Name: Ultra High Voltage Power Transformer
    • Transformer Type: Oil-Immersed Power Transformer
    • Application: Long-distance bulk power transmission, UHV substations
    • Installation: Outdoor
    • Cooling Method: ONAN / ONAF / OFAF / OFWF
    • Phases: Single-phase or Three-phase
    • Frequency: 50 Hz / 60 Hz
    • Standards:
  • IEC 60076 Series
  • IEC 60076-1 / 60076-3 / 60076-5
  • IEEE C57 (upon request)
  • GB/T 1094 (China)
  1. Rated Data
ParameterSpecification
Rated Power500 MVA – 1500 MVA (customizable)
Highest Voltage for Equipment1000 kV AC / ±800 kV DC / ±1100 kV DC
Rated Voltage (HV)1000 kV / ±800 kV / ±1100 kV
Rated Voltage (LV / MV)500 kV / 400 kV / 220 kV
Rated CurrentAccording to rated power and voltage
Vector GroupYNyn0 / YNyn0d11 / customer specified
Tap ChangerOLTC (On-Load Tap Changer)
Tapping Range±10% or as specified
Tapping Step1.25% / 1.5%
  1. Electrical Characteristics
    • Short-Circuit Impedance: 12% – 30% (customizable)
    • Short-Time Withstand Current: According to IEC 60076-5
    • Insulation Level:
  • Lightning Impulse Withstand Voltage (LIWV): Up to 3000 kV
  • Switching Impulse Withstand Voltage (SIWV): According to UHV standards
    • Partial Discharge Level: ≤ 100 pC
    • No-Load Loss: Optimized low-loss core design
    • Load Loss: According to IEC / project specifications
  1. Insulation System
  • Insulation Medium: Mineral oil / Natural ester oil (optional)
  • Solid Insulation: High-density cellulose paper & pressboard
  • Insulation Structure: Oil-paper composite insulation system
  • Bushing Type: Oil-Impregnated Paper (OIP) / Resin-Impregnated Paper (RIP)
  • Creepage Distance: Designed according to pollution level (IEC 60815)
  1. Core & Windings
  • Core Material: High-permeability grain-oriented silicon steel
  • Core Type: Five-limb or multi-limb core structure
  • Windings: Continuously transposed copper conductors (CTC)
  • Mechanical Strength: Designed to withstand extreme short-circuit forces
  • Shielding: Electrostatic and magnetic shielding to reduce losses and hotspots
  1. Cooling System
  • Cooling Modes:
  • ONAN – Oil Natural / Air Natural
  • ONAF – Oil Natural / Air Forced
  • OFAF – Oil Forced / Air Forced
  • OFWF – Oil Forced / Water Forced
    • Radiators: Detachable radiator banks
    • Oil Pumps & Fans: Redundant configuration for high reliability
    • Temperature Rise: According to IEC 60076 limits
  1. Tank & Mechanical Design
  • Main Tank: Welded steel structure with reinforced mechanical strength
  • Conservator: Diaphragm or bladder type oil conservator
  • Surface Treatment: Sand blasting + anti-corrosion painting system
  • Color: RAL customizable
  • Seismic Design: Optional, according to IEEE / IEC seismic requirements
  1. Monitoring & Protection
  • Oil temperature indicators (OTI / WTI)
  • Online dissolved gas analysis (DGA) – optional
  • Buchholz relay
  • Pressure relief device
  • Oil level indicator
  • Online bushing monitoring system – optional
  • Fiber optic temperature monitoring – optional
  1. Tests

Routine Tests

  • Winding resistance measurement
  • Voltage ratio and phase displacement
  • Insulation resistance and dielectric tests
  • No-load and load loss measurement

Type Tests

  • Temperature rise test
  • Lightning impulse test
  • Switching impulse test
  • Short-circuit withstand test
  • Partial discharge measurement

Special Tests (Optional)

  • Sound level test
  • Zero-sequence impedance test
  • Seismic test
  1. Environmental Conditions
  • Ambient Temperature:
  • Maximum: +40°C
  • Minimum: −25°C (lower on request)
    • Altitude: ≤ 1000 m above sea level
    • Pollution Level: Light / Medium / Heavy (as per IEC 60815)
    • Installation: Outdoor, UHV substation
  1. Typical Applications
  • Ultra High Voltage AC transmission systems (1000 kV)
  • UHV DC converter stations (±800 kV / ±1100 kV)
  • Long-distance bulk power transmission
  • National grid backbone networks
  1. Compliance & Certification

This Ultra High Voltage Power Transformer is designed, manufactured, and tested in full compliance with IEC 60076 series, GB/T 1094, and relevant IEEE standards, ensuring reliable operation in UHV transmission networks worldwide.

  1. Customization Options
  • Rated voltage and power tailored to project requirements
  • Ester oil for enhanced fire safety and environmental protection
  • High seismic resistance design
  • Advanced online monitoring systems
  • Special insulation design for extreme pollution or altitude

Summary

The Ultra High Voltage Power Transformer is a critical component of modern bulk power transmission systems. Designed for maximum reliability, ultra-low losses, and long service life, it meets the stringent requirements of UHV AC and DC transmission projects worldwide.

 

DATA DOWNLOAD
  • I have read and agree to the Privacy Policy.
E-mail WhatsApp